When an aircon stops cooling well, many people assume it needs a gas top-up. Sometimes that is right, but often the real cause is something simpler. Here is how to tell the difference before you spend money on it.
Refrigerant is not used up like fuel
The refrigerant in an aircon circulates in a sealed loop. In a healthy system it does not run out. If the level is low, there is usually a leak somewhere, so simply topping up without finding the leak may give only temporary relief.
Causes of weak cooling that are not gas
- Dirty filters or a clogged coil that restrict airflow.
- A dirty outdoor unit that cannot release heat.
- A faulty fan motor or capacitor.
- A thermostat or sensor problem.
- A room that is too hot for the unit’s size, for example after adding a west-facing window.
Because of these, we usually clean the unit and check airflow first. See aircon not cold for the checks we run.
Signs that gas may be the issue
- The unit runs but blows only slightly cool air even after a clean.
- Ice forms on the indoor coil or on the outdoor pipes.
- A hissing or bubbling sound near the pipes.
- The room cooled well in the past, but has declined gradually over months.
In these cases a technician should check pressure and look for leaks before adding refrigerant. Read more on our gas top-up page.
Why a leak check matters
Joints, flare connections and old pipework are common leak points, especially in older installations. Fixing the leak keeps cooling stable and avoids repeated top-ups. Older flats such as those in Kebun Baru and Henderson may have units that have been in place for many years, so an inspection before any top-up is sensible.
If you are unsure, describe the symptoms to Aircon2u and see the price list for current rates.